ANENG AN870 19999 counts Auto Range Digital Precision multimeter True-RMS NCV Ohmmeter AC/DC Voltage Ammeter Transistor Tester

ANENG AN870 19999 counts Auto Range Digital Precision multimeter True-RMS NCV Ohmmeter AC/DC Voltage Ammeter Transistor Tester



  • Measuring Inductance Range: NO
  • Dimensions: 180x90x45 mm
  • DC Voltage: 19.999mV/199.99mV/1.9999V/19.999V/199.99V/1000V
  • DIY Supplies: Electrical
  • AC Voltage: 19.999mV/199.99mV/1.9999V/19.999V/199.99V/750ACV
  • Operating Mode: Auto/Manual Ranging
  • Measuring Resistance Range: 199.99/1.9999K/19.999k/199.99k/1.9999M/19.999M/199.99M
  • Brand Name: ANENG
  • Model Number: AN870
  • Operating Temperature: 0 - 40 ℃
  • AC Current: (199.99-1999.9)uA/(19.999-199.99)mA/1.9999-199.99uA
  • DC Current: (199.99-1999.9)uA/(19.999-199.99)mA/1.9999-199.99uA
  • Display Type: Digital Display
  • Measuring Capacitance Range: 9.999nF/99.99nF/999.9nF/9.999uF/99.99uF/999.9uF/9.999MF
  • Frequency: 99.99Hz/999.9Hz/9.999KHz/99.99KHz/999.9KHz/9.999MHz
  • Temperature: -20~1000C/-4~1832F
  • Diode Test: Yes
  • NCV: Yes
  • Continuity: Yes
  • Auto-Power Off: Yes
  • Battery Type: 2*1.5V AA (not included)

  • ANENG AN870 19999 counts Auto Range Digital Precision multimeter True-RMS NCV Ohmmeter AC/DC Voltage Ammeter Transistor Tester

    Please note: the device is an auto-ranging multimeter,so the mV function is always jumps, this is not defect, it is correct

     

    Package includes:
    1 x Multimeter  
    1 x Test lead+temperature sensor 
    2 x Test Leads (Red+black) 
    1 x 16 in 1 Multifunctional Test Line 
    1 x Storage Bag 
    1 x User\'s Manual ( English ) 
     
    436-1-2-3IMG_3856-1IMG_3824
    1011
    The product is battery-powered with true-rms, LCD display and backlight.
    1. Do NOT exceed the “maximum value” indicated in the Specification;
    2. Do NOT input voltage at the Current Mode, the Resistance Mode, the Diode  Mode,
        the Continuity Mode, or the Temperature Mode;
    3. Do NOT use the product when the batteries or the battery cover is not placed  properly;
    4. Turn off the product and remove the test leads from the test points before  changing batteries or fuses.
    5. Do not input voltage exceeds 36V DC or 25V AC when you are at the setting of measuring current.
    12

    Comments

    Popular posts from this blog

    8L Min Electric High Pressure Airless Spraying Machine 980 Two Guns Wall Painting Sprayer FOR Emulsion

    USB MACH3 100Khz Breakout Board 4 Axis Interface Driver Motion Controller For Cnc Router Milling Machine

    GRBL Open Source Firmware 3axis CNC Controller Board Laser Engraving Machine PCB Board Wood Router Controller